Add to Cart
IG541 Inert Gas Fire Suppression System For Storage Tank Room Without Residue
Technical parameter:
No. | Specification | IG541(52% nitrogen;40% argon,8carbon dioxide) | |||
1 | Capacity | 80Ltr | 90ltr | ||
2 | Working Pressure | 15MPa | 20MPa | 20MPa | 30MPa |
3 | Device Model | QMH15/80 | QMH20/80 | QMH20/90 | QMH30/90 |
4 | Model Number | QM H20/90-XL-12 | |||
5 | Discharge Time | ≤60S | |||
6 | Driving Bottle Group Pressure | 6MPa | |||
7 | Maximum Working Pressure at 50℃ | 211.15kg/M³/281.06kg/M³ | |||
8 | Fire Extinguishing Method | Full Flooding | |||
9 | Activation Method | Automatic, Pneumatic, Manual, Mechanical Emergency Operation | |||
10 | Applications | Storage Tank Room |
Description:
The IG541 Inert Gas Fire Suppression System has emerged as a highly effective and advanced solution for protecting storage tank rooms, offering unparalleled advantages over traditional fire suppression methods such as dry powder extinguishers. One of the most significant benefits of the IG541 system is its ability to suppress fires without leaving any residue. Dry powder extinguishers, while widely used in industrial settings, often create a messy aftermath that can be both time-consuming and costly to clean up. The fine powder particles can settle on sensitive equipment, surfaces, and stored materials, leading to contamination, corrosion, or damage. This is particularly problematic in storage tank rooms, where the integrity of tanks, valves, and other critical components must be maintained to prevent leaks, spills, or environmental hazards. In contrast, the IG541 Inert Gas Fire Suppression System uses a blend of inert gases—nitrogen, argon, and carbon dioxide—that are naturally occurring and completely non-corrosive. When discharged, these gases disperse evenly throughout the protected area, reducing oxygen levels to a point where combustion cannot sustain itself, all while leaving no trace behind. This makes the IG541 Inert Gas Fire Suppression System an ideal choice for environments where cleanliness and operational continuity are paramount.
Another key advantage of the IG541 Inert Gas Fire Suppression System is its environmental safety and sustainability. Unlike dry powder extinguishers, which may contain chemicals that pose risks to human health or the environment, IG541Inert Gas Fire Suppression System is composed entirely of naturally occurring gases with zero ozone depletion potential (ODP) and no global warming potential (GWP). This aligns perfectly with modern regulatory standards and corporate sustainability goals, making it a preferred choice for environmentally conscious organizations. Additionally, the IG541 Inert Gas Fire Suppression System is safe for use in occupied spaces, as it reduces oxygen levels just enough to extinguish fires while maintaining breathable conditions for personnel. Dry powder extinguishers, on the other hand, can create hazardous conditions due to reduced visibility from the powder cloud and potential respiratory irritation for individuals exposed to the discharge. Furthermore, the IG541 system’s rapid response time ensures that fires are suppressed within seconds, preventing them from escalating into larger, more destructive events. Its automatic detection and activation mechanisms provide an added layer of reliability, whereas dry powder extinguishers often rely on manual intervention, which can delay response times and allow fires to spread unchecked.
Application:
Storage tank rooms are critical facilities that store flammable liquids or gases, requiring a highly reliable fire suppression system. IG541 Inert Gas Fire Suppression System is specifically designed to meet these demands. When a fire is detected, the IG541 Inert Gas Fire Suppression System rapidly discharges the inert gas mixture, reducing oxygen levels to extinguish the fire within seconds. This rapid response prevents the fire from spreading and minimizes damage to storage tanks and surrounding equipment. The system’s residue-free operation ensures that there is no need for post-fire cleanup, reducing downtime and associated costs. This is particularly important in storage tank rooms, where even brief interruptions can disrupt supply chains and result in significant financial losses. IG541 Inert Gas Fire Suppression System also offers flexibility in system design, allowing it to protect multiple storage tanks or zones within a single facility. Its ability to operate in occupied spaces without posing health risks to personnel further enhances its suitability for storage tank rooms. By adopting IG541, facilities can ensure the safety of their assets, protect their investments, and maintain compliance with stringent fire safety regulations while supporting environmental sustainability.
Company profile:
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd., established in 2017 with a registered capital of RMB 10 million, is a leading provider of advanced fire safety solutions headquartered in Dongzhou Industrial Park, Xintang Town, Zengcheng District, Guangzhou. Committed to innovation and reliability, the company specializes in state-of-the-art clean gas automatic fire extinguishing systems, including FM200(HFC-227ea),Novec1230,IG541 and IG100 systems, complemented by sophisticated gas fire alarm control panels.These products are widely adopted across diverse sectors, such as municipal infrastructure, power plants, telecommunications, healthcare facilities, and construction projects, thanks to their efficiency, safety, and environmental sustainability.
Supported by over 30 patents and a team with more than eight years of collective expertise in fire protection engineering, Xinlin Fire offers comprehensive services spanning system design, engineering, and seamless project execution. Operating from a modern 2398 - square - meter facility, Xinlin Fire integrates automated production lines and cutting - edge testing equipment to ensure consistent, high - quality output.
The company's production system has passed the dual certifications of the internationally authoritative SGS factory inspection certification and the German TÜV Rheinland factory inspection. At the same time, it has obtained ISO 9001 (Quality Management System), ISO 14001 (Environmental Management System), and ISO 45001 (Occupational Health and Safety Management System). Ensure that every link of the product from production to delivery complies with international standards. In addition, we also provide Chemical Data Sheets (MSDS) to comprehensively ensure the compliance and safety of product transportation, storage and use. Choosing us means choosing professionalism and trust.
Q1: Are you a manufacturer or a trading company?
A1: We are a professional manufacturer specializing in gas fire suppression systems.
Q2: Can you give me a sample order?
A2: Yes, of course you can. We welcome you to order samples to test and check the product quality. Provide mixed samples.
Q3: Do you offer OEM products?
A3: Yes, we welcome your own designs and drawings.
Q4: Where is your factory located?
A4: Our factory is situated in the East Lake Industrial Park of XinTang Town, Zengcheng District, Guangzhou City, Guangdong Province, China.
Q5: How can I get to your factory?
A5: Due to convenient transportation, you can reach us by taxi or by subway. If taking the subway, please take Line 13 to Shacun Station. Before disembarking, kindly inform us in advance, and we will arrange for a comfortable business van to pick you up from there.